| Automated Irradiator Systems, Controllers, and Software | |||||
| print this page Hopewell Designs, Inc. | |||||
|
Hopewell Designs, Inc. manufactures calibration systems for radiation detection instruments and personnel dosimetry. These systems produce radiation fields of known intensity; instruments or dosimeters being calibrated are placed in the fields to confirm accurate operation. A typical calibrator consists of radioactive sources, radiation shielding, a mechanism for exposing the sources, a linear track for positioning the item(s) being calibrated, safety systems, and a computer controller. |
|||||
|
|||||
|
Installed irradiator systems include: X-ray beam, gamma beam, neutron/gamma low scatter,
self-contained "box" calibrators, and well irradiators.
In addition, ancillary systems include linear positioning systems, video monitoring systems, jigs and fixtures,
calibration phantoms, radiation monitors, warning lights and indicators, safety interlock systems,
source transfer systems, and custom shielding. |
|||||
|
|
|||||
|
|||||
| Our automated software package places most irradiator operations under computer control.
The operator has full control over the system, but by handling the tedious and repetitive
tasks, the computerized controls free the operator to focus on areas where expertise
is required. |
|||||
| With the wide range of variables and program parameters provided, supervisory personnel may readily customize the software to meet specific needs. | |||||
|
|
|||||
| About the Software | |||||
| Our Automated Irradiator Control systems are based on National Instruments LabVIEW™ and National Instruments interface hardware. This offers assurance that our automated controls are usable, understandable, customizable, maintainable, and upgradable. | |||||
(Click on the image below for more information about its sections ...)
Environment Section
Safety and System Status Section
Source and Exposure Section
Time Section
AutoSetup Section
Linear Positioning System (LPS) Control Section
Irradiator Calibration Section
|
|||||
|
return to top
|
|||||
Indicates the status of the door interlock; i.e., whether the entry door
to the exposure area is open or closed
Indicates whether the System Enable key switch is in the Enabled position.
The key cannot be removed when the switch is in the enabled position,
and this is the only key that fits the door to the exposure area.
Indicates whether system is ready to make an exposure
Indicates whether the source is in its Safe position (green),
Exposed position (flashing red and yellow), or in motion (flashing red)
Indicates the overall status of the system: Idle, Ready to Expose,
Exposrue in Progress, Record to Database, Source Moving, Printing Report, etc.
Mode of operation: Normal for normal exposures;
Daily QC for day-to-day comparisons of exposure levels,
Irradiator Calibration for a fully automated tool to calibrate the irradiator.
Message box - displays error messages and user instructions
Press this button to clear the Message area
|
Safety and System Status Section | ||||
|
|||||
|
|
|||||
|
return to top
|
|||||
|
Source and Exposure Section | ||||
|
|||||
| The operator may set the Exposure Rate and / or the Exposure. The position of the instrument and / or the amount of exposure time are calculated including a correction for source decay. | |||||
|
|
|||||
|
return to top
|
|||||
| Time Section | |||||
|
|||||
| The operator may preset the time to zero to manually control the exposure. The operator also may reset the Elapsed Time counter at any time. | |||||
|
|
|||||
|
return to top
|
|||||
| Linear Positioning System (LPS) Control Section | |||||
|
|||||
|
|||||
| When an Exposure Rate or Exposure is specified, the system calculates a position, automatically compensating for source decay. | |||||
|
|
|||||
|
return to top
|
|||||
|
Environment Section | ||||
|
|||||
|
|
|||||
|
return to top
|
|||||
| AutoSetup Section | |||||
| A database and user interface is provided to allow operators and / or supervisors to pre-define multi-step procedures. In the AutoSetup section, the operator may choose one of these procedures. This section contains controls to select a Procedure and a Step within that procedure. | |||||
|
|
|||||
|
return to top
|
|||||
|
Irradiator Calibration Section | ||||
|
|||||
|
|
|||||
| Hopewell Designs, Inc. 5940 Gateway Drive, Alpharetta, GA 30004 770-667-5770 / FAX 770-667-7539 sales@hdirad.com |
|||||